Eurocode 7

Eurocode 7 — Earthquake (EN 1998-5:2004)

EN 1998-5:2004Revision 1Required FoS ≥ 1Seismic design situation

Use it in Slope

In a design, choose it under Analyze → Design factor set, and the PDF report runs it too.

Checked against the standard · Not yet validated

Known limitations

  • ψ2 is 0.3 for every variable load; EN 1990 gives ψ2 per load category (0.3 for imposed loads A/B, 0 for traffic, snow and wind).
  • Reinforcement is unfactored (Slope convention, not validated): EN 1998-5:2004 gives no seismic reinforcement factors and EN 1997-1 Table A.19 covers persistent and transient situations only; the absence of a factor does not show the unfactored capacity is adequate.
  • The cyclic undrained strength τcy,u (γτcy = 1.25) has no input.
  • Pseudo-static analysis must not be used for soils that develop high pore pressures or lose stiffness under cyclic loading (4.1.3.3(8)P).

Values

Actions

Soil weightγUnfavorable×1.00
Favorable×1.00
Permanent loadγGUnfavorable×1.00
Favorable×1.00
Variable loadγQUnfavorable×0.30
Favorable×0.00
Seismic coefficientγE×1.00

Resistance

Earth / global resistanceγRe÷1.00

Materials

Effective cohesionγc′÷1.25
Friction (tanφ′)γφ÷1.25
Undrained strength (cu)γcu÷1.40
Shear strength (other models)—÷1.25

Sources

Document: EN 1998-5:2004

Actions

FactorValueSource
Soil weight — unfavorable×1.004.1.3.4(4)P, PDF p18 · Not yet validated
Soil weight — favorable×1.004.1.3.4(4)P, PDF p18 · Not yet validated
Permanent load — unfavorable×1.004.1.3.4(4)P, PDF p18 · Not yet validated
Permanent load — favorable×1.004.1.3.4(4)P, PDF p18 · Not yet validated
Variable load — unfavorable×0.302.1(2)P · Slope convention · Not yet validated — ψ2 = 0.3 for every variable load (EN 1990 imposed loads A/B); EN 1990 gives ψ2 per load category.
Variable load — favorable×0.002.1(2)P · Slope convention · Not yet validated — The seismic combination (EN 1990 6.4.3.4) takes accompanying variable actions only; a helping one is omitted.
Seismic coefficient×1.004.1.3.3(5)P, PDF p17 · Slope convention · Not yet validated — Slope applies kh and kv as entered: enter kh = 0.5·α·S (×ST where 4.1.3.2(2) requires it).

Materials

FactorValueSource
Effective cohesion÷1.253.1(3), PDF p15 · Slope convention · Not yet validated — 3.1(3) lists no γc′; 1.25 by analogy with EC7 M2.
Friction (tanφ′)÷1.253.1(3), PDF p15 · Not yet validated
Undrained strength (cu)÷1.403.1(3), PDF p15 · Not yet validated
Shear strength (other models)÷1.253.1(3), PDF p15 · Slope convention · Not yet validated — γqu = 1.4 applies to unconfined-strength models; other strength models take 1.25 as for EC7 M2.

Resistance

FactorValueSource
Earth / global resistance÷1.004.1.3.4(4)P, PDF p18 · Not yet validated