BS 8002:2015
Clay, IP 80, medium strength
BS 8002:2015, Figures 1–2, Table 2 — typical valuesRevision 1
Use it in Slope
In a design, add it from Materials → Quick add → Built-in soils. The material keeps this citation, and the PDF report prints its caveats.
Typical values — not a substitute for site investigation.
Values
| Value | SI | Imperial | Source range |
|---|---|---|---|
| γ | 20.5 kN/m³ | 130.5 pcf | γ 16.5–20.5 kN/m³ |
| γsat | 20.5 kN/m³ | 130.5 pcf | γsat 16.5–20.5 kN/m³ |
| c′ | 0.0 kPa | 0.0 psf | — |
| φ′ | 18.0° | 18.0° | — |
Working
- φ′cv = 18° at IP 80 % (Table 2; equation (7) gives 18.2°).
- γ and γsat 16.5–20.5 kN/m³ (clay, medium undrained strength, Slope's choice; Figures 1–2).
- c′cv = 0 (cl 4.3.1.4.9).
Notes
- Other undrained-strength classes (Figures 1–2, kN/m³): very low 14–18, low 15–19, high 18–22, very high 18.5–23.5 above / 19.5–23.5 below, extremely high 21–24.
Caveats
- For use in the absence of reliable test results (BS 8002 cl 4.3.1.4.2 and 4.3.1.4.8).
- The preset's unit weights are the top of the source's range, a default to check against the case: BS 8002 asks for the superior or inferior value by its effect (cl 4.3.1.3.4 / 4.3.1.4.4), and which bound is unfavourable depends on the loading and groundwater.
- Where pre-existing slip surfaces exist, residual strength may govern (BS 8002 cl 4.3.1.4.11).
- The preset leaves the AS 4678 soil condition at in situ; for a placed fill set the material's soil condition to match (some AS 4678 modes, such as direct sliding across a layer, are not given for in-situ soil).
Source
- BS 8002:2015
- Clauses: cl 4.3.1.4.2–4.3.1.4.11; Figures 1–2; equation (7); Table 2
- Printed pages: 14–20
- PDF pages: 20–26